Modulation
Message on specific channel to control the modulation.
Data is send in the following form:
1011nnnn Control Change; n=Channel [0.15= Channel 1.16]
00000001 Modulation
0vvvvvvv v=Modulation [0.127]
Transmission will take 0.96 ms.
See Also:Control Change